{"id":315,"date":"2026-02-17T15:21:25","date_gmt":"2026-02-17T11:51:25","guid":{"rendered":"https:\/\/romantaco.com\/en\/?post_type=product&#038;p=315"},"modified":"2026-02-17T15:21:25","modified_gmt":"2026-02-17T11:51:25","slug":"condumax-ii","status":"publish","type":"product","link":"https:\/\/romantaco.com\/en\/product\/condumax-ii\/","title":{"rendered":"Condumax II"},"content":{"rendered":"<h3><strong>Measurement Technology<\/strong><\/h3>\n<p>The <strong>Condumax II<\/strong> employs two synergistic measurement methods:<\/p>\n<p><strong>Hydrocarbon Dew\u2011Point Measurement \u2013 Dark Spot\u2122 Chilled Mirror:<\/strong><br \/>\nThe primary hydrocarbon dew-point channel uses the <strong>Dark Spot\u2122 direct chilled\u2011mirror technique<\/strong>. In this method, a <strong>Peltier\u2011cooled mirror surface<\/strong> within the hydrocarbon sensor cell is progressively cooled under electronic control. When hydrocarbon condensate begins to form on the mirror, a <strong>secondary optical effect<\/strong> is detected as a reduction in scattered light intensity from a collimated beam reflected from the mirror\u2019s surface. This point of optical change is used to define the <strong>hydrocarbon dew point<\/strong> directly, with objective and repeatable results.<\/p>\n<p>The multi\u2011stage Peltier cooling system provides <strong>controlled cooling<\/strong> to achieve measurement depressions as low as \u0394\u201155\u202fK beyond ambient analyzer temperature, ensuring accurate detection of condensate formation.<\/p>\n<p>This direct optical condensation measurement is <strong>fundamental and primary<\/strong>, meaning there is no reliance on empirical correlations \u2014 the dew point is determined by the actual onset of condensation, making the technique inherently accurate and stable.<\/p>\n<p><strong>Water Dew\u2011Point Measurement \u2013 Ceramic Moisture Sensor (Optional):<\/strong><br \/>\nFor simultaneous water dew point analysis, Condumax II can accommodate an optional <strong>water dew\u2011point channel<\/strong> based on Michell\u2019s <strong>Ceramic Metal\u2011Oxide Moisture Sensor<\/strong>. This sensor utilizes a ceramic metal\u2011oxide impedance sensing element that responds to changes in moisture content in the gas stream with measured impedance changes. These changes are converted into dew\u2011point values and moisture content in various units (\u00b0C, \u00b0F, ppmV, mg\/m\u00b3, etc.), providing complementary data to hydrocarbon dew-point measurements.<\/p>\n<h3><strong>Detailed Technical Specifications:<\/strong><\/h3>\n<ul>\n<li><strong>Hydrocarbon Dew\u2011Point Measurement Frequency:<\/strong> ~6 cycles\/hour recommended (up to 12 cycles\/hour maximum).<\/li>\n<li><strong>Hydrocarbon Sample Pressure Range:<\/strong> 15\u2026100\u202fbarg.<\/li>\n<li><strong>Water Dew\u2011Point Sample Pressure Range:<\/strong> 30\u2026138\u202fbarg.<\/li>\n<li><strong>Hydrocarbon DP Measurement Resolution:<\/strong> 0.1\u202f\u00b0C (0.18\u202f\u00b0F).<\/li>\n<li><strong>Water Dew\u2011Point Range:<\/strong> \u2013100\u2026+20\u202f\u00b0C dew point.<\/li>\n<li><strong>Environmental Conditions:<\/strong> Suitable for indoor\/outdoor operation down to \u201320\u202f\u00b0C up to +50\u202f\u00b0C with maximum 95\u202f% relative humidity.<\/li>\n<\/ul>\n<p><strong>Applications:<\/strong><br \/>\nCondumax II is engineered for continuous on\u2011line dew point analysis in applications such as <strong>natural gas processing, transmission pipeline moisture control, custody transfer verification, and LNG facility monitoring<\/strong>. It delivers accurate hydrocarbon and water dew point data essential for gas quality assurance and process optimization.<\/p>\n","protected":false},"excerpt":{"rendered":"<h3><strong>Product Overview<\/strong><\/h3>\n<p>The <strong>Condumax II Hydrocarbon and Water Dew Point Analyzer<\/strong> is a fully automatic, <strong>continuous online analyzer<\/strong> for measurement of both <strong>hydrocarbon dew point<\/strong> and <strong>water dew point<\/strong> in natural gas and other process gases. It combines a hydrocarbon dew-point measurement cell with an optional water dew-point sensor in a single, explosion\u2011proof enclosure suitable for hazardous area installation.<\/p>\n<h3><strong>Key Technical Specifications:<\/strong><\/h3>\n<ul>\n<li><strong>Hydrocarbon Dew\u2011Point Measuring Technique:<\/strong> Dark Spot\u2122 direct chilled\u2011mirror fixed sample analysis detecting condensate through optical measurement.<\/li>\n<li><strong>Hydrocarbon Dew\u2011Point Accuracy:<\/strong> \u00b10.5\u202f\u00b0C (single or multiple condensable component analysis).<\/li>\n<li><strong>Hydrocarbon Sample Flow:<\/strong> ~0.03\u202fm\u00b3\/hr (0.5\u202fNl\/min) \u2013 alarm standard.<\/li>\n<li><strong>Hydrocarbon Operating Pressure:<\/strong> 15\u2026100\u202fbarg.<\/li>\n<li><strong>Water Dew\u2011Point Measuring Technique (Optional):<\/strong> Ceramic metal\u2011oxide moisture sensor.<\/li>\n<li><strong>Water Dew\u2011Point Range:<\/strong> \u2013100 to +20\u202f\u00b0C (calibrated).<\/li>\n<li><strong>Water Dew\u2011Point Accuracy:<\/strong> \u00b11\u202f\u00b0C (\u201359 to +20\u202f\u00b0C), \u00b12\u202f\u00b0C (\u2013100 to \u201360\u202f\u00b0C).<\/li>\n<li><strong>Resolution:<\/strong> 0.1\u202f\u00b0C (both hydrocarbon and water dew point).<\/li>\n<li><strong>Pressure Measurement Resolution:<\/strong> 0.1\u202fMPa \/ barg and 1\u202fpsig units.<\/li>\n<li><strong>Sample Gas Supply:<\/strong> Natural gas up to 100\u202fbarg (regulated).<\/li>\n<li><strong>Enclosure:<\/strong> Explosion\u2011proof cast enclosure with internal heat for condensation protection, IP66 rating.<\/li>\n<li><strong>Sample Connections:<\/strong> 1\/8\u201d or 1\/4\u201d NPT female for both hydrocarbon and water channels.<\/li>\n<li><strong>Operating Environment:<\/strong> \u201320\u2026+50\u202f\u00b0C, up to 95\u202f% RH.<\/li>\n<li><strong>Power Supply:<\/strong> 90\u2013260\u202fV AC, 50\/60\u202fHz (125\u202fW main unit).<\/li>\n<li><strong>Outputs:<\/strong> Modbus RTU, RS485, two user\u2011configurable 4\u201320\u202fmA outputs.<\/li>\n<li><strong>Certifications:<\/strong> IECEx, ATEX, UKCA, cQPSus, GOST Ex.<\/li>\n<\/ul>\n<p>The optional <strong>water dew-point measurement<\/strong> channel uses the <strong>Michell Ceramic Moisture Sensor<\/strong> for water dew-point and moisture content outputs in units including \u00b0C, \u00b0F, lb\/MMscf, mg\/m\u00b3 and ppmV.<\/p>\n","protected":false},"featured_media":316,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[19,17],"product_tag":[],"class_list":{"0":"post-315","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-humidity-and-water-dew-point-analyzer","7":"product_cat-process-analyzers","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/romantaco.com\/en\/wp-json\/wp\/v2\/product\/315","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/romantaco.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/romantaco.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/romantaco.com\/en\/wp-json\/wp\/v2\/comments?post=315"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/romantaco.com\/en\/wp-json\/wp\/v2\/media\/316"}],"wp:attachment":[{"href":"https:\/\/romantaco.com\/en\/wp-json\/wp\/v2\/media?parent=315"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/romantaco.com\/en\/wp-json\/wp\/v2\/product_brand?post=315"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/romantaco.com\/en\/wp-json\/wp\/v2\/product_cat?post=315"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/romantaco.com\/en\/wp-json\/wp\/v2\/product_tag?post=315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}